VISIÓN GENERAL

MoTeC’s unique M1 technology redefines the meaning of customisation, delivering total control without compromise, while highly advanced security strategies make these ECUs ideal for both category managed and unrestricted applications.

The M150 is a Port Injection ECU that offers full control for most modern engines.


LICENCIA

At the time of purchase, an M1 ECU needs to be Licensed for use with a particular Package or a Development Licence.

Packages

An M1 Package is the file that is loaded into an M1 ECU. An M1 Package contains the entire ECU state including the tuning data, worksheets, security and the M1 firmware. M1 Packages themselves are opened and modified in M1 Tune.

  • GP PackagesMoTeC offers a suite of General Purpose Packages that allow an M1 ECU to be tuned to any number of applications. The flexibility of these GP Packages enables a tuner to configure the same ECU to very different engine setups, including those with road vehicle systems to maintain, such as air conditioning.GP Packages are available in variants such as Advanced, Race, Paddle shift and Direct Injection.
  • Targeted Packages
    • Public PackagesThese are Packages specifically developed in-house by MoTeC engineers for a particular engine or vehicle. In some cases this includes integration with vehicle control systems beyond the engine, for example, stability control and cruise control.For some targeted applications, the M1 ECU is available in a complete Plug-In Kit which includes any additional hardware that may be required.
    • Partner PackagesThese are Packages developed by a MoTeC Partner Developer. It may be based on a Public Package with unique features added by the developer to offer a specific solution.MoTeC support staff will not provide assistance for these Packages, it will be provided by the Partner.
    • Category PackagesThese are Packages developed in-house by MoTeC engineers written specifically for the category, limiting the functionality to the class requirements.
Development Licence

When an M1 ECU is teamed with a Development Licence, it allows users to develop unique control strategies, or make modifications to existing M1 Packages. Using M1 Build software, experienced code writers can tailor the functionality of a single ECU or create a Partner Package for ongoing sales.


ESPECIFICACIONES BASICAS

Injector
  • Peak and Hold or Saturated Injector Outputs: 12
  • Max Peak / Hold Current: 12 A / 4 A
  • Low Side Injector Outputs*: 6
Ignition
  • Low Side Ignition Outputs*: 12

Unused ignition and injector outputs can be used for other functions like cam or boost control solenoid operation

Auxiliary Outputs
  • Half Bridge Output: 10
Inputs
  • Universal Digital Input: 12
  • Digital Input: 4
  • Analogue Voltage Input: 17
  • Analogue Temperature Input: 6
  • Narrowband Lambda*: 2
  • Knock: 4

Narrowband Lambda sensor function not supported in GP Packages

Data
  • CAN Bus / RS232 / LIN: 3 / 1 / 1
  • Logging Memory: 250 MB
Physical
  • Dimensions: 162 x 127.5 x 40.5 mm
  • Weight: 445 g
  • Connector: 2 x 34 pin + 2 x 26 pin Tyco
Electrical
  • Supply Voltage – Normal Operation: 8 V to 32 V
  • Typical no-load supply current: 0.34 A at 13.8 V supply

SEGURIDAD

The M1’s advanced security system is based on public-key cryptography – the cornerstone of secure internet transactions – so it is virtually impossible to change the ECU function without authorised permission. Security is enforced by the ECU and protected by a microprocessor with integrated measures to prevent tampering.

A password feature grants different levels of access for different users, e.g. an engine tuner, a drive train tuner and a data analysis engineer. This is also suitable for Control ECU applications. Scrutineering teams can be given access to extra information and are able to lock down selected parts of the ECU, while other team members can be granted access to selected tuning parameters.


FUNCIONES

  • Small and light in robust magnesium enclosure
  • Latest generation high performance processor
  • Suitable for modern engines with DBW, Cam Control and multiple CAN buses
  • Robust and comprehensive security features
  • Flexible tuning software
  • Programmable injector drive characteristics
  • Programmable digital inputs for Ref/Sync, wheel speeds etc.
  • Programmable trigger levels and diagnostics
  • All Low Side and Half Bridge outputs have PWM capability
  • With Logging Level 3 enabled:
    • Advanced logging features, high speed, multiple logs (with access logins)
    • Logging sets can be partitioned with access logins granting different information for different users from the same device. For example judicial (scrutineering) and team member access

MEJORAS

Logging Upgrades

There are three Logging Licence levels. The level determines the number of channels and sample rates available. Logging Level 1 Licence is diagnostic logging, which comes standard with the product, and includes a fixed log set and sample rates.

  • Logging Level 2 Licence: includes 2 log sets, up to 200 channels (including Level 1 diagnostics logging) and a maximum 200 Hz sample rate.
  • Logging Level 3 Licence: includes 8 log sets, up to 2000 channels (including Level 1 diagnostics logging) and a maximum 1000 Hz sample rate.
Pro Analysis

The Pro Analysis upgrade is the professional version of MoTeC’s i2 data analysis software and provides advanced mathematics, multiple overlay laps, and unlimited components, workbooks and worksheets.


SOFTWARE

Microsoft Windows™ based software:

  • M1 Tune: PC Tuning software used to tune fuel and ignition, and set up sensors, outputs and available functions.
  • M1 Build: PC software used to create a custom software Package with user specific functions.

CABLEADO Y CONECTORES

Communication (UI)

User communication with the ECU requires an Ethernet connection. A cable providing an Ethernet plug and suitable pin termination for the M1 mating connector can be purchased from MoTeC Dealers.

Inputs

Voltage range: -30 V to 35 V

Outputs

Maximum current on outputs:

  • Low Side Injector outputs: max 3.5 A, RMS 2 A
  • Half Bridge outputs: Low Side 12 A, High Side 9 A, RMS 4 A
Wire Gauges
  • Battery
    • Bat_Pos: all pins should be connected with AWG20, AWG18, or AWG16 wire to a switched battery supply
    • Bat_Neg: all pins should be connected with AWG20, AWG18, or AWG16 wire to a chassis ground or battery negative terminal. ‘Star’ distribution should be employed to ensure that no ECU ground currents are mixed with actuator ground currents
    • Recommended minimum supply wiring: 3x Bat_Pos, 4x Bat_Neg
    • Max supply voltage 35 V
  • OutputsDepending on the current draw for some outputs, a minimum wire gauge is recommended for safe operation:
    • Low Side Ignition, Peak Hold Injector, Low Side Injector outputs: AWG20 (ideally) and AWG22 (optional)
    • Half Bridge and Full Bridge outputs: these outputs may be used to drive low side actuators, throttle servos, and direct injection pumps. Wire size should be chosen to suit the current requirements of the actuator device. For example, throttle servos and direct injection pumps should use AWG18 or AWG20 wiring
    • Half Bridge or Peak Hold Injector outputs provide internal recirculation circuitry, whereas all Low Side outputs do not. In applications where camshaft solenoids and other inductive devices cannot be driven from outputs with internal recirculation circuitry, external recirculation by means of a diode can be installed to prevent slow turn-off of some devices


M150 PINOUT

M150 Connector A – 34 way

Mating Connector: Tyco Superseal 34 Position Keying 2 – MoTeC #65067

Pin NumberDesignationFull NameOE PinFunctionDescription
A01AT5Analogue Temperature Input 51k Pull up to SEN_5V_C
A02AT6Analogue Temperature Input 61k Pull up to SEN_5V_C
A03AV15Analogue Voltage Input 15
A04AV16Analogue Voltage Input 16
A05AV17Analogue Voltage Input 17
A06IGN_LS9Low Side Ignition 9
A07IGN_LS10Low Side Ignition 10
A08IGN_LS11Low Side Ignition 11
A09IGN_LS12Low Side Ignition 12
A10SEN_5V0_C1Sensor 5.0V C
A11LA_NB1Lambda Narrow Input 1
A12LA_NB2Lambda Narrow Input 2
A13KNOCK3Knock Input 3
A14KNOCK4Knock Input 4
A15DIG2Digital Input 2
A16DIG3Digital Input 3
A17DIG4Digital Input 4
A18SEN_5V0_C2Sensor 5.0V C
A19SEN_5V0_B2Sensor 5.0V B
A20LINLIN Bus
A21RS232_RXRS232 Receive
A22RS232_TXRS232 Transmit
A23DIG1Digital Input 1
A24BAT_NEG3Battery Negative
A25BAT_NEG4Battery Negative
A26SEN_0V_C1Sensor 0V C
A27SEN_0V_C2Sensor 0V C
A28CAN3_HICAN Bus 3 High
A29CAN3_LOCAN Bus 3 Low
A30CAN2_HICAN Bus 2 High
A31CAN2_LOCAN Bus 2 Low
A32BAT_NEG5Battery Negative
A33SEN_0V_B1Sensor 0V B
A34SEN_0V_A1Sensor 0V A
M150 Connector B – 26 way

Mating Connector: Tyco Superseal 26 Position Keying 3 – MoTeC #65068

Pin NumberDesignationFull NameOE PinFunctionDescription
B01OUT_HB9Half Bridge Output 9
B02OUT_HB10Half Bridge Output 10
B03UDIG8Universal Digital Input 8
B04UDIG9Universal Digital Input 9
B05UDIG10Universal Digital Input 10
B06UDIG11Universal Digital Input 11
B07UDIG12Universal Digital Input 12
B08INJ_LS5Low Side Injector 5
B09INJ_LS3Low Side Injector 3
B10AV9Analogue Voltage Input 9
B11AV10Analogue Voltage Input 10
B12AV11Analogue Voltage Input 11
B13BAT_POSBattery Positive
B14INJ_LS6Low Side Injector 6
B15INJ_LS4Low Side Injector 4
B16AV12Analogue Voltage Input 12
B17AV13Analogue Voltage Input 13
B18AV14Analogue Voltage Input 14
B19BAT_POSBattery Positive
B20OUT_HB7Half Bridge Output 7
B21OUT_HB8Half Bridge Output 8
B22INJ_PH9Peak Hold Injector 9
B23INJ_PH10Peak Hold Injector 10
B24INJ_PH11Peak Hold Injector 11
B25INJ_PH12Peak Hold Injector 12
B26SEN_5V0_ASensor 5.0V A
M150 Connector C – 34 way

Mating Connector: Tyco Superseal 34 Position Keying 1 – MoTeC #65044

Pin NumberDesignationFull NameOE PinFunctionDescription
C01OUT_HB2Half Bridge Output 2
C02SEN_5V0_ASensor 5.0V A
C03IGN_LS1Low Side Ignition 1
C04IGN_LS2Low Side Ignition 2
C05IGN_LS3Low Side Ignition 3
C06IGN_LS4Low Side Ignition 4
C07IGN_LS5Low Side Ignition 5
C08IGN_LS6Low Side Ignition 6
C09SEN_5V0_BSensor 5.0V B
C10BAT_NEG1Battery Negative
C11BAT_NEG2Battery Negative
C12IGN_LS7Low Side Ignition 7
C13IGN_LS8Low Side Ignition 8
C14AV1Analogue Voltage Input 1
C15AV2Analogue Voltage Input 2
C16AV3Analogue Voltage Input 3
C17AV4Analogue Voltage Input 4
C18OUT_HB1Half Bridge Output 1
C19INJ_PH1Peak Hold Injector 1
C20INJ_PH2Peak Hold Injector 2
C21INJ_PH3Peak Hold Injector 3
C22INJ_PH4Peak Hold Injector 4
C23INJ_LS1Low Side Injector 1
C24INJ_LS2Low Side Injector 2
C25AV5Analogue Voltage Input 5
C26BAT_POSBattery Positive
C27INJ_PH5Peak Hold Injector 5
C28INJ_PH6Peak Hold Injector 6
C29INJ_PH7Peak Hold Injector 7
C30INJ_PH8Peak Hold Injector 8
C31OUT_HB3Half Bridge Output 3
C32OUT_HB4Half Bridge Output 4
C33OUT_HB5Half Bridge Output 5
C34OUT_HB6Half Bridge Output 6
M150 Connector D — 26 way

Mating Connector: Tyco Superseal 26 Position Keying 1 – MoTeC #65045

Pin NumberDesignationFull NameOE PinFunctionDescription
D01UDIG1Universal Digital Input 1
D02UDIG2Universal Digital Input 2
D03AT1Analogue Temperature Input 11k Pull up to SEN_5V_A
D04AT2Analogue Temperature Input 21k Pull up to SEN_5V_A
D05AT3Analogue Temperature Input 31k Pull up to SEN_5V_B
D06AT4Analogue Temperature Input 41k Pull up to SEN_5V_B
D07KNOCK1Knock Input 1
D08UDIG3Universal Digital Input 3
D09UDIG4Universal Digital Input 4
D10UDIG5Universal Digital Input 5
D11UDIG6Universal Digital Input 6
D12BAT_BAKBattery Backup
D13KNOCK2Knock Input 2
D14UDIG7Universal Digital Input 7
D15SEN_0V_ASensor 0V A
D16SEN_0V_BSensor 0V B
D17CAN1_HICAN Bus 1 High
D18CAN1_LOCAN Bus 1 Low
D19SEN_6V3Sensor 6.3V
D20AV6Analogue Voltage Input 6
D21AV7Analogue Voltage Input 7
D22AV8Analogue Voltage Input 8
D23ETH_TX+Ethernet Transmit+Ethernet Green/White
D24ETH_TX-Ethernet Transmit-Ethernet Green
D25ETH_RX+Ethernet Receive+Ethernet Orange/White
D26ETH_RX-Ethernet Receive-Ethernet


DIMENSIONES Y MONTAJE

Measurements in mm.

Mounting

The product provides through holes for mounting. See drawing for details.

The recommended mounting torque value is 5 Nm. The torque value must not exceed 5.5 Nm.


INFORMACION DEL PRODUCTO

Compliances

M1 ECUs are designed for use in a vehicle. As such, this product complies with the following standard:

  • AS/NZS CISPR 22 Edition 6 (2008) : Information technology equipment Class B

Installation

IP Rating (dust or water ingress)

This product should be installed in a protected location where only occasional water splashing occurs and where the exposure to dust does not exceed conditions typical for vehicle installations.

Operating Temperature Range

This product is designed for an internal operating temperature range of -40 °C to 85 °C.

It should be installed in a location with sufficient air circulation and be shielded against thermal emissions from surrounding components.

Vibration Statement

This product is designed to withstand vibrations typical for normal vehicle installations.

It should not be exposed to severe and lasting vibrations. For example, the product should not be installed in solid connection to vibrating components like engines or undamped vehicle structures.

Safety

  • For safe operation, use only undamaged.
  • Minimal force should be exerted to plug in connectors.
  • These devices may output voltages which may constitute a risk to human safety. Appropriate precautions must be taken:
    • At no time operate the device with faulty, bare or exposed wiring.
    • Adhere to the normal supply voltage limits as listed in the Basic Specifications section
    • Adhere to wire gauges as listed in Wiring and Connecting.

Repair

Do not attempt to open and/or repair the device.

Disposal

This product should be disposed of in accordance with relevant national regulations for disposal of electronic waste. It does not contain hazardous materials which might be subject to specific materials regulations.


DESCARGAS

NameVersion / PartPublishedDownload
i2 Pro (64 bit)1.1.5.0192ago 2023
DOWNLOAD
i2 Pro1.1.4.0456feb 2019
DOWNLOAD
i2 Standard (64 bit)1.1.5.0193ago 2023
DOWNLOAD
i2 Standard1.1.4.0457feb 2019
DOWNLOAD
M1 Build (x64)1.4.3.0356oct 2023
DOWNLOAD
M1 Build1.4.1.0326may 2021

DOWNLOAD
M1 Tune1.4.0.0302dic 2023
DOWNLOAD