VISION GENERAL

MoTeC’s LTC NTK (Lambda to CAN module) monitors, controls and diagnoses an NTK Lambda sensor, transmitting Lambda readings on a CAN bus.

When using multiple LTC NTKs, up to 32 Lambda sensors can be configured on a single CAN bus for simultaneous monitoring by an ECU or logging device.


ESPECIFICACIONES

  • Provides accurate Lambda measurement, even when exhaust gas temperature is changing rapidly (heating or cooling).
  • Calibrated by the user for a particular sensor using the initial sensor factory calibration, the free air calibration or the referenced gas calibration.
  • Pre-configured to suit a single unit installation. If necessary, the configuration can be adjusted; see the Configuration section for more details.
  • Units marked with a 2 or higher under the barcode are able to transmit extended Lambda values (Rich Lambda).

COMPATIBILIDAD

MoTeC ECU: M1 Series, M84, M400, M600, M800, M880

MoTeC Display/Loggers: All C Series Display Loggers, ACL, CDL3 (and discontinued models: SDL, SDL3, ADL, ADL2, ADL3)


COMUNICACIONES DEL ORDENADOR

A MoTeC gateway device is required to communicate with the LTC on CAN. Such devices include:

  • M1 Series ECUs
  • All C Series Display Loggers, ACL, ADL3, SDL3, CDL3
  • UTC (USB to CAN) #61059

ESPECIFICACIONES

Inputs/Outputs
  • 1 x NTK Lambda sensor (MoTeC #57007)
  • Power supply voltage 11 V – 16 V
  • Power supply current 110 mA typical plus the sensor heater current. Heater current is typically 0.5 A – 1 A and up to 2 A on startup.
Communications
  • 1 x CAN — using LTC Manager, configurable to: 125 Kbps, 250 Kbps, 500 Kbps or 1 Mbps
Physical
  • Dimensions: 38 x 26 x 14 mm, excluding wiring looms and connectors
  • Weight: 62 g
  • 1 x 4 pin male DTM connector (power/CAN)
  • 1 x mating connector for NTK Lambda sensor
  • Maximum ambient temperature: 100 °C

SOFTWARE

For multiple installations, LTC Manager software allows all units to be simultaneously managed and diagnosed.

The software is used to:

  • Configure and calibrate all units on the CAN bus
  • Display readings and diagnostics
  • Configure CAN transmission addresses
  • Control free air sensor calibration
  • Update unit firmware

CONFIGURACION

MoTeC LTCs come pre-configured to suit a single LTC unit installation. By default, the initial factory sensor calibration is used and the CAN address is 460.

It is only necessary to use LTC Manager if installing multiple LTC units, or if changes to the default settings are required.


DIMENSIONES Y MONTAJE

All dimensions in mm.


CONECTORES PINOUTS

Connector A (and B for Dual version)

NTK sensor connector

Mating connector: supplied on sensor

PinWire ColourDescription
1BlueHeater +
2YellowHeater –
3OrangeRc
4BlackSensor 0 V
5Not connected
6GreyVs
7WhiteIp
8BlackSensor 0 V
Power / CAN Connector

DTM 4pin (M) (#68055)

Mating connector: DTM 4pin (F) #68054

PinWire ColourDescription
1BlackBattery –
2GreenCAN Lo
3WhiteCAN Hi
4RedBattery +

CABLEADO

To power the LTC, connect to either the ignition switch for fast sensor startup or the fuel pump relay to prevent accidental battery drainage.

Wiring example

For information on wiring a CAN bus with several LTCs and any number of other CAN devices (as per the example), refer to the relevant device manual.


DESCARGAS

NameVersion / PartPublishedDownload
LTC LTCD Manager1.3.0.0002may 2019DOWNLOAD

MANUAL

NameVersion / PartPublishedDownload
LTC LTCD LTCN User Manualfeb 2017DOWNLOAD