VISIÓN GENERAL

The L120 Enclosed Logger is a powerful control device and fully programmable data logger, all in one compact unit.

The L120 acquires data from other devices, such as an ECU, for logging and telemetry. It can be used in a wide range of applications, either as a standalone unit or integrated with other electronic devices such as displays and PDM’s.

Note: An L120 Enclosed Logger with USB Logging is also available. (Part #18045)


CARACTERISTICAS

  • Suitable for bikes, cars, marine and industrial applications
  • 120MB internal logging memory
  • GPS Lap Timing
  • Supports Wideband Lambda from MoTeC PLMs or LTCs
  • Easily integrates with MoTeC CAN based products such as ECUs and expanders
  • Full I/O expansion available with use of E888, E816 expanders

ACCESORIOS

  • 62204 – L120 LOOM
  • 61259 – L120 INPUT LOOM

MEJORAS OPCIONALES

  • 29624 – L120 T2 TELEMETRY
  • 29621 – L120 PRO ANALYSIS
  • 29601 – L120 I/O

ESPECIFICACIONES

Communications
  • 2 x configurable CAN buses, with individually programmable CAN bus speeds.
    • One can be used as RS232 Receive
  • 2 x dedicated RS232 ports
    • One with Transmit and Receive
    • One with Receive only
Inputs

(* available via I/O upgrade)

  • 2 x digital inputs
  • 3 x speed inputs
  • 6* x analogue voltage inputs:
    • 4* x 0 to 5.46 V, 1.33 mV resolution
    • 2* x 0 to 15.0 V, 3.66 mV resolution
  • 2* x analogue temperature inputs, 0 to 15 V, 3.66 mV resolution
Outputs

(* available via I/O upgrade)

  • 4* x low side outputs PWM or switched operation
    • 0.5 A maximum, current limited and thermal overload protected
Logging

(available via upgrades)

  • 120 MB internal logging memory
  • Logging rates up to 500 samples per second
  • Fast Ethernet download
Internal Sensors
  • 3-axis accelerometer, detection range: +/- 5G
  • Sensor supply voltage
  • Battery voltage
Power supply
  • Operating voltage: 6 to 32 V DC
  • Operating current: 0.5 A typical at 14 V (excl. sensor currents)
  • Reverse battery protection
  • Battery transient protection
Sensor supply currents
  • 5 V sensor supply: 0.25 A maximum
  • 8 V sensor supply: 0.25 A maximum
Operating temperature
  • Internal: -20 °C to 70 °C
  • Typical ambient temperature range in free air: -20 °C to 55 °C
Physical
  • Unit size: 134.5 x 103.9 x 20.2 mm excluding connector
  • Weight 310 g
  • 1 x 34 pin waterproof connector
  • The device is rated to IP67

COMPATIBILIDAD

  • MoTeC ECUs: All models (some earlier models may require an additional adaptor in conjunction with the RS232 adaptor)
  • MoTeC Displays/Loggers: All
  • MoTeC Expanders: E816 and, E888 expanders.
  • MoTeC Accessories: SLM, PLM, LTC, BR2, PDM, GPS, ADR2, V2 etc.
  • Many non-MoTeC devices

SOFTWARE

  • Microsoft Windows based software
  • Used for setup and management of the data logging system, providing:
    • Configuration of the inputs, ouputs, data logging and calculations.
    • Offline generation of a configuration file that can then be sent to the device.
    • Channel monitoring
    • Firmware updating and extensive help screens
  • i2 Data Analysis software provides the tools for comprehensive data analysis. Standard or Pro* version available
  • T2 Telemetry* software

(* available via upgrades)


CABLEADO DE LA ECU

When using an M4, M48 or M8 ECU, the should be connected via RS232. For some ECUs, a PCI cable may also be required.

The Display Logger should be connected via the CAN bus when using an M1 or ‘hundred series’ ECU(M400/M600/M800/M880) or M84, and any number of other CAN devices. Example:

Detailed wiring information is available in the help topics of the C125 Dash Manager software at

DIMENSIONES Y MONTAJE

Measurements in mm.


PINOUT

Mating Connector: Part number 65044

PinNameStandard FunctionOptional Function (with I/O upgrade)
1E-TX–Ethernet Transmit –
2E-TX+Ethernet Transmit +
3AV1Analogue Voltage Input 1
4AV2Analogue Voltage Input 2
5AV3Analogue Voltage Input 3
6AV4Analogue Voltage Input 4
78VSensor 8 V
85VSensor 5 V
90VSensor 0 V
10E-RX–Ethernet Receive –
11E-RX+Ethernet Receive +
12AV5Analogue Voltage Input 5
13AV6Analogue Voltage Input 6
14DIG1Digital Input 1
15DIG2Digital Input 2
16AT1Analogue Temp Input 1
17AT2Analogue Temp Input 2
18CAN1LCAN1 Lo
19CAN1HCAN1 Hi
20RS232-1 TXRS232-1 Transmit Output
21SPD1Speed Input 1
22SPD2Speed Input 2
23SPD3Speed Input 3
24Not usedNot used
25RS232-2 RXRS232-2 Receive Input
26CAN2LCAN2 Lo / RS232 Ground Input
27CAN2HCAN2 Hi / RS232 Receive Input
28RS232-1 RXRS232-1 Receive Input
29AUX1Auxiliary Output 1
30AUX2Auxiliary Output 2
31AUX3Auxiliary Output 3
32AUX4Auxiliary Output 4
33BAT+Battery Positive
34BAT–Battery Negative

DESCARGAS

NameVersion / PartPublishedDownload


C125 Dash Manager

6.40.0.J6
mar 2022DOWNLOAD
Display Creator (64 bit)
6.4.1.0333
ago 2023DOWNLOAD
i2 Pro (64 bit)1.1.5.0192ago 2023DOWNLOAD

i2 Pro

1.1.4.0456
feb 2019DOWNLOAD
i2 Standard (64 bit)
1.1.5.0193
ago 2023DOWNLOAD

i2 Standard

1.1.4.0457
feb 2019DOWNLOAD